|
|
|
|
|
|
|
|
|
|
|
Use with HS chimney roof flashing to insure water tight installation.
|
Designed to fit on the round chimney pipe just above the roof flashing. The upper edge of the collar should be waterproofed with plastic sealer to prevent any water from leaking between the collar and chimney pipe. Part is tightened with screws or tabs after proper positioning.
|
Designed to fit on the round chimney pipe just above the roof flashing. The upper edge of the collar should be waterproofed with plastic sealer to prevent any water from leaking between the collar and chimney pipe. Part is tightened with screws or tabs after proper positioning.
|
|
|
|
|
|
|
|
|
|
|
|
|
Diamond shaped 1/2 in x 1 in mesh, 18-8 stainless steel. Fits same size round chimney top. Keeps foreign objects out of chimney.
|
Included in ceiling support assembly, roof support assembly and tee assembly.
|
Included in ceiling support assembly, roof support assembly and tee assembly.
|
|
|
|
|
|
|
|
|
|
|
|
|
Diamond shaped 1/2 in x 1 in mesh, 18-8 stainless steel. Fits same size round chimney top. Keeps foreign objects out of chimney.
|
Used along the wall to provide for 2 in clearance and assure stability. Useful for suspending offsets. Required at 8 ft or closer intervals to stabilize the chimney, wherever it is supported along a vertical wall.
|
Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used to trim the ceiling when a chimney is supported from above and extended down into room. Also used in conjunction with firestop/joist shield.
|
Selkirk SURE-TEMP Locking Band, Stainless Steel, 6 in Dia, Suitable for: Chimney Pipe
|
Inner and outer pipe. The outer pipe, made of galvanized steel, provides cooling air necessary to maintain safe chimney temperatures, while the inner pipe, made of stainless steel, emits gases out of the fireplace. Snap- lock design. 12 in standard pipe (12 ID, 15 3/8 OD) UL127 listed 1700 deg pipe.
|
|
|
|
|
|
|
|
|
|
|
|
|
Provides a finished appearance where the chimney passes through a sloped ceiling. Matte black finish. Adjusts to multiple roof pitches. Covers 4 in space around chimney pipe (or 2 in further than the required clearance).
|
Standard flashings fit various pitch roofs. Its double seamed construction protects from water leakage.
|
Provides a finished appearance where the chimney passes through a sloped ceiling. Matte black finish. Adjusts to multiple roof pitches. Covers 4 in space around chimney pipe (or 2 in further than the required clearance).
|
|
|
|
|
|
|
|
|
|
|
|
|
Used to trim the ceiling when a chimney is supported from above and extended down into room. Also used in conjunction with firestop/joist shield.
|
Selkirk Drip less Smoke Stove Pipe Adapter, 430 Stainless Steel, Dimensions: 15-3/4 In L
|
Interior resupport assembly allows for two different methods of chimney resupport. The first method is used at the immediate section of chimney above the upper elbow of an offset. With the appropriate fire stop/joist shield (JS) in place, clamp the support band around chimney and attach with six-sheet metal screws. The second means of support is used primarily when the immediate sections of the upper offset do not pass through a joist area and resupport is necessary. The support band is clamped around the chimney immediately below a locking band. In both methods, the straps are nailed to suitable framing at two inch clearance. The 18 ft limit of supportable chimney length applies.
|
|
|
|
|
|
|
|
|
|
|
|
|
Use with HS chimney roof flashing to insure water tight installation.
|
Selkirk SURE-TEMP Insulated Thimble, Wall Mounting
|
Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more.
|
|
|
|
|
|
|
|
|
|
|
|
|
This new design gives you the flexibility of securing the 5, 6, 7 or 8 in Dia chimney with a heavy-duty band. The band allows you to slide the installed length verticaly to properly position this section in the system. Installation requirements are the same as our standard RSP. The URSA can hold 30 ft of pipe total only 20 ft.
|
Part of the chimney system roof assembly, the round top is designed with a dome to exclude rain and leaves and a lower skirt to deflect wind for proper chimney draft. In the Sure-Temp-Type HT Chimney (5 in, 6 in, 7 in and 8 in sizes) the round top is designed with three legs that slide down over the outside of the chimney. A cinch band is then positioned over the legs and tightened to hold the top firmly in place. This design makes cap removal for cleaning a breeze.
|
Standard flashings fit various pitch roofs. Its double seamed construction protects from water leakage.
|
|
|
|
|
|
|
|
|
|
|
|
|
The Type HT wall support kit has been tested for use fully enclosed and has been designed in 5, 6, 7 and 8 in sizes to carry up to 60 ft of height at 2 in from wall. The capacity of the larger sizes, 10, 12 and 14 in, is 40 ft of chimney. The wall support is intended for use with the Insulated Tee as an interior or exterior support where the chimney has a lateral connection.
|
Provides a secure attachment for the chimney to smoke chamber outlet on masonry fireplaces, reducing footing loads and speeding construction. Stainless steel and heavy-gauge steel construction for long life. Retains chimney with a twist-lock connection.
|
Used wherever a ceiling support, finish support, firestop or joist shield is installed below an open attic. Required to guard against the hazard of blown-in or blanket insulation filling any framed opening or contacting the chimney and possible storage of combustibles against the chimney.
|
|
|
|
|
|
|
|
|
|
|
|
|
Flashings are used to seal the opening where the chimney penetrates the roof and to divert rain and snow down from the roof and away from the chimney system.A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings. To determine your roof pitch, measure the number of inches from the end of a level ruler down to the roof. This is the rise for 12 in of run. A rise of 5 in is a 5/12 pitch. 4 in, a 4/12 pitch and more.
|
Used with tee branch and chimney section to provide proper clearance to combustible materials. Matte black painted surface for interior wall eliminates need for trim plate.
|
Used whenever there is a need to stabilize the chimney above the roof level. The purpose of the bracing is to hold the chimney against wind load and to prevent damage from static and sliding snow. It should be used, at a midpoint on the chimney. Bracket adjusts from 4 to 6 ft.
|
|